REVERBERI s.r.l. - Tel. 0039 (0) 522 875159 - Fax 0039 (0) 522 875579 - e-mail reverberisrl@gmail.com
REVERBERI s.r.l. - Tel. 0039 (0) 522 875159 - Fax 0039 (0) 522 875579 - e-mail reverberisrl@gmail.com

SERENA 18lt – 23lt

SERENA

451__dsf33045

499__dsf3304

Serena is available on request in the black and gray colors

CE 0051

Medical device 
SERENA 18lt - 23lt


 Code: 18lt: M9010/100
            23lt: M9010/101

Last generation steam autoclave completely automatic, operating at distilled water, sterilization chamber and steam generator in stainless steel. Designed to increase security in the study, for this and for informed choice provides only Class B cycles.


BASIC FEATURES


Device comply with the European Regulations

  • Available in two versions:
               Sterilization chamber capacity 18 lt.
               Sterilization chamber capacity 23 lt.
  • Two sterilization temperatures: 121°C or 134°C
  • Possibility of two “special cycles” fully programmable
  • 3 Universal sterilization cycles of type B
  • 3 test cycles: Vacuum test - Bowie & Dick test/ Helix test -
    Spores test
  • Prion cycle
  • Startup cycle postponed
  • Motorized door
  • Display for operations view with date, time and number of cycles
  • Drying with vacuum pump
  • Additional drying at the end of the cycle
  • Operator code
  • Automatic water loading with pump
  • SD Card
  • Possibility of automatic filling with Kiara-Tec depurator connection
  • Printer predisposition
  • Labeler predisposition


TECHNICAL FEATURES

  • Power supply: 230Vac  - 50 Hz
  • Power rating: 2200 W
  • Chamber dimensions: Ø236  x 360 (18 lt.) INOX
                                           Ø236 x 530 (23lt.) INOX  
  • Dimensions: 470x 400 x 630 mm (18lt.)
                          470 x 400 x 700 mm  (23lt.)
  • Gross weight:  51Kg (18lt.)
                              56Kg (23lt.)
  • Operating pressure: 2.1 - 1.1 Bar
  • Temperature max: 180°C

ACCESSORIES

BAR CODE READER

April 4, 2014

Schermata 2014-04-04 alle 18.22.13

BIOLOGICAL TEST

April 4, 2014

Bowie&Dick

BOWIE & DICK TEST

April 4, 2014

CHEMICAL TEST

CHEMICAL TEST

March 17, 2017

177_2635

ENVELOPES HOLDER

April 4, 2014

filtro

FILTER BACTERIOLOGICAL

April 4, 2014

Helix test

HELIX TEST

April 4, 2014

chiave serena

KEY DOOR SERENA

April 4, 2014

Kiaratec sfondo
KRISTAL WATER

KRISTAL WATER

March 21, 2017

M904

LABELING

April 4, 2014

241_detergente-4240

LIQUID SANITIZER

April 4, 2014

Sigillatrice
Mobile

PIECE OF COLUMN

March 16, 2017

M9004

PRINTER FOR AUTOCLAVES

April 4, 2014

SD
Carrello
471_etichettatrice1

UNION PRINT – LABELING

April 4, 2014

termolog

VAPOR LINE TEST

April 4, 2014